Cont’d) – Yaskawa Varispeed-686SS5 CIMR-SSA User Manual
Page 45

46
The following procedures show how to change variable torque motor selection to
constant torque motor selection and set the motor related constants.
Table 13
Motor Related Constants Setting
Step
Description
Key Sequence
Digital Operator Display
1
Power ON
• Displays speed reference value.
G
REMOTE LEDs (SEQ, REF) ON.
2
Move to program mode.
When inputting the values other than motor
nameplate values, execute steps to be-
low.
3
7
DRIVE
PRGM
Constant No. display
3
• Move to access level (A1-01).
RESET
4
• Verify the set value.
DATA
ENTER
5
• Change to ADVANCED.
RESET
6
• Write-in the value.
DATA
ENTER
Displays for 0.5 seconds.
Setting completed.
7
• Return to constant No. display.
DSPL
8
Variable torque/constant torque motor selection
• Move to variable torque/constant torque
motor selection (E1-14).
RESET
9
• Verify the set value.
DATA
ENTER
(Initial setting: variable torque motor)
10
• Select constant torque motor.
RESET
11
• Write-in the value.
DATA
ENTER
Displays for 0.5 seconds.
Setting completed.
12
• Return to constant No. display.
DSPL
(Cont’d)
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)