beautypg.com

Caution, Warning – Yaskawa Varispeed-686SS5 CIMR-SSA User Manual

Page 5

background image

6

INSTALLATION

CAUTION

(Ref. page)

S

Lift the cabinet by the base. When moving the unit, never lift by the front

cover.
Otherwise, the main unit may be dropped causing damage to the unit.

16

. . . . . . . . . .

S

Mount the inverter on nonflammable material (i.e. metal).

Failure to observe this caution can result in a fire.

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

S

When mounting units in an enclosure, install a fan or other cooling device

to keep the intake air temperature below 45_C.
Overheating may cause a fire or damage to the unit.

16

. . . . . . . . . . . . . . . . . . . . . . . .

WIRING

WARNING

(Ref. page)

S

Only commence wiringafter verifyingthat thepower supply is turnedOFF.

Failure to observe this warning can result in an electric shock or a fire.

20

. . . . . . . . .

S

Wiring should be performed only by qualified personnel.

Failure to observe this warning can result in an electric shock or a fire.

20

. . . . . . . . .

S

When wiring the emergency stop circuit, check the wiring thoroughly

before operation.
Failure to observe this warning can result in personal injury.

20

. . . . . . . . . . . . . . . . .

S

Make sure to ground the ground terminal

.

(Ground resistance
200V class: 100Ω or less, 400V class: 10Ω or less)
Failure to observe this warning can result in an electric shock or a fire.

24

. . . . . . . . .