3
WIRING
35
Table 7
Closed-Loop Connectors
Wire Size mm
2
Terminal Screw
Closed-Loop Connectors
0 5
M3.5
1.25 - 3.5
0.5
M4
1.25 - 4
0 75
M3.5
1.25 - 3.5
0.75
M4
1.25 - 4
1 25
M3.5
1.25 - 3.5
1.25
M4
1.25 - 4
M3.5
2 - 3.5
M4
2 - 4
2
M5
2 - 5
M6
2 - 6
M8
2 - 8
M4
5.5 - 4
3 5 / 5 5
M5
5.5 - 5
3.5 / 5.5
M6
5.5 - 6
M8
5.5 - 8
M5
8 - 5
8
M6
8 - 6
M8
8 - 8
14
M6
14 - 6
14
M8
14 - 8
22
M6
22 - 6
22
M8
22 - 8
30 / 38
M8
38 - 8
50 / 60
M8
60 - 8
50 / 60
M10
60 - 10
80
M10
80 - 10
100
M10
100 - 10
100
100 - 12
150
M12
150 - 12
200
200 - 12
325
M12 × 2
325 - 12
325
M16
325 - 16
When determining wire size, consider voltage drop. Select a wire size so that voltage drop will
be less than 2% of the normal rated voltage. Voltage drop is calculated by the following equa-
tion:
Phase-to-phase voltage drop (V)
=√ 3 ¢ wire resistance (Ω/km) ¢ wiring distance (m) ¢ current (A) ¢ 10
-3
NOTE
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)