NOTES:
(1)
Based on an N.E.C. standard 4-pole motor for max. applicable motor output.
(2)
Shows deceleration torque for an uncoupled motor decelerating from 60 Hz in 0.1 seconds.
(3)
Four of these input signals are present on the control terminal, and three are controlled via DeviceNet communications.
(4)
Two photo-coupler outputs are present on the control terminal, and one NO contact output is controlled via DeviceNet
communications.
(5)
Contact Yaskawa for wiring distances greater than 328 ft. (100 m).
(6)
Temperature during shipping (for short periods of time).
SECTION B. All Drives (Continued)
Motor overload protection
Electronic thermal overload relay
Motor coasts to stop at approx. 250%
Instantaneous overcurrent
of Drive current
Motor coasts to stop after 1 min. at 150% of
Overload
Drive rated current (7)
Motor coasts to stop if DC bus voltage exceeds
Overvoltage
410VDC (230V), 820VDC (460V)
Motor coasts to stop when DC bus voltage is
Undervoltage
210VDC or less (230V), 400VDC or less (460V)
The following operations are selectable:
Momentary Power Loss
• Not provided (stops if power loss is 15 ms or longer)
• Automatic restart at recovery from 0.5 sec. power loss
• Automatic restart
Heatsink overheat
Protected by electronic circuit
Independently programmable during accel and
Stall prevention level
constant-speed running. Selectable during decel.
Ground fault
Protected by electronic circuit (overcurrent level)
ON until the DC bus voltage becomes 50V or less.
Power charge indication
RUN lamp says ON or digital operator LED stays ON.
(Charge LED is Provided for 400V)
Cooling Fan Fault
Protected by electronic circuit
Run/stop input
2-Wire or 3-Wire
Seven of the following input signals are selectable:
(3)
Forward/reverse run (3-Wire sequence), fault reset,
external fault (NO/NC contact input), multi-step speed operation,
Multi-function input
Jog command, accel/decel time select,
external baseblock (NO/NC contact input), speed search command,
accel/decel hold command, LOCAL/REMOTE selection,
DeviceNet communication/control circuit terminal selection, emergency stop
fault emergency stop alarm
Following output signals are selectable
(1 NO/NC contact output, 2 photo-coupler outputs):
(4)
Fault, running, zero speed, at frequency, frequency detection
Multi-function output
(output frequency ≤ or ≥ set value), during overtorque detection,
during undervoltage detection, minor error, during baseblock, operation mode,
inverter run ready, during fault retry, during UV, during speed search,
data output through DeviceNet communication
Open Loop Vector Control, full-range automatic torque boost, auto restart,
Standard functions
upper/lower frequency limit, DC injection braking current/time at start/stop,
frequency reference gain/bias, prohibited frequencies,
analog meter calibrating gain, S-curve accel/decel, slip compensation,
DeviceNet communications,
frequency reference from digital operator pot
Status indicator LEDs
RUN and ALARM LEDs provided as standard
Digital Operator
Monitors frequency reference, output frequency,
output current, FWD/REF selection
Terminals
Screw terminals for both main circuit and control circuit
Wiring distance between
Drive and motor
328 ft (100 m) or less
(5)
Enclosure
Nema Type 1
Cooling method
Self-cooling/cooling fan
Input Power
Voltage: 11 to 25VDC
Current: 40mA
DeviceNet Specification
Conformance level 16: Passed
DeviceNet Profile
AC Drive Device Type 2
Connector Type
5-pin open-style screw connector
Physical Layer Type
Isolated Physical Layer
CAN transceiver + photo coupler
MAC ID Setting
2 Rotary-switches: MAC ID 0 to 63; Parameter setting available
Baud Rate
A rotary-switch: 125/250/500 kbaud/Auto Baud; Parameter setting available
Supported Message
Group 2 only server
Explicit and Polled I/O messaging
I/O Assembly Instance
Input: 5 types (4-8 bytes)
Output: 5 types (4-8 bytes)
Ambient temperature
14 to 104°F (-10 to 40°C)
Humidity
95% RH or less (non-condensing)
Storage temperature
(6)
-4 to 140°F (-20 to 60°C)
Location
Indoor (free from corrosive gases or dust)
Elevation
3,280 feet (1,000 m) or less
Vibration
Up to 1G, at less than 20 Hz;
up to 0.2G, at 20 to 50 Hz
Standard Specifications (Continued)
Protective Functions
Environmental
conditions
Other Functions
Input signals
Output signals
Display