6 related drive parameters – Yaskawa Modbus TCP/IP Installation User Manual
Page 32

6 Related Drive Parameters
32
YASKAWA ELECTRIC TOBP C730600 57B 1000-Series Option SI-EM3 Installation Manual
F6-07
(3A8)
NetRef/ComRef
Selection
Function
0: Multi-step speed reference disabled, (F7 functionality)
1: Multi-step speed reference allowed, (V7 functionality)
Default: 0
Range: 0, 1
F6-08
(36A)
Reset
Communication
Related
Parameters
Determines if communication-related parameters F6- and F7-
are set back to original default values when the drive is
initialized using parameter A1-03.
0: Do not reset parameters
1: Reset parameters
Default: 0
Range: 0, 1
F7-01
(3E5)
IP Address 1
Sets the static/fixed IP address.
Parameter F7-01 sets the most significant octet.
Default: 192
Range: 0 to 255
F7-02
(3E6)
IP Address 2
Sets the static/fixed IP address.
Parameter F7-02 sets the second most significant octet.
Default: 168
Range: 0 to 255
F7-03
(3E7)
IP Address 3
Sets the static/fixed IP address.
Parameter F7-03 sets the third most significant octet.
Default: 1
Range: 0 to 255
F7-04
(3E8)
IP Address 4
Sets the static/fixed IP address.
Parameter F7-04 sets the fourth most significant octet.
Default: 20
Range: 0 to 255
F7-05
(3E9)
Subnet Mask 1
Sets the static/fixed Subnet Mask.
Parameter F7-05 sets the most significant octet.
Default: 255
Range: 0 to 255
F7-06
(3EA)
Subnet Mask 2
Sets the static/fixed Subnet Mask.
Parameter F7-06 sets the second most significant octet.
Default: 255
Range: 0 to 255
F7-07
(3EB)
Subnet Mask 3
Sets the static/fixed Subnet Mask.
Parameter F7-07 sets the third most significant octet.
Default: 255
Range: 0 to 255
F7-08
(3EC)
Subnet Mask 4
Sets the static/fixed Subnet Mask.
Parameter F7-08 sets the fourth most significant octet.
Default: 0
Range: 0 to 255
F7-09
(3ED)
Gateway Address
1
Sets the static/fixed Gateway address.
Parameter F7-09 sets the most significant octet.
Default: 192
Range: 0 to 255
F7-10
(3EE)
Gateway Address
2
Sets the static/fixed Gateway address.
Parameter F7-10 sets the second most significant octet.
Default: 168
Range: 0 to 255
No.
(Addr. H)
Name
Description
Values