beautypg.com

11 troubleshooting – Yaskawa SI-EN3 Installation User Manual

Page 48

background image

11 Troubleshooting

48

YASKAWA ELECTRIC TOBP C730600 58B 1000-Series Option SI-EN3 Installation Manual

Minor Faults and Alarms

LED Operator Display

Fault Name

oFC00

Option Fault (CN5-C)
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option
connected to the drive.

Connect the correct option to CN5-A.

LED Operator Display

Fault Name

oFC02

Option Fault
Option Flash write mode.

Cause

Possible Solution

Options AI-A3 or DI-A3 are
connected to the CN5-B port
while an option connected to
CN5-A.

• Only one type of AI-A3, DI-A3 or SI-†† option can be connected to the drive.
• The SI-EN3 option can only be connected to CN5-A

LED Operator Display

Minor Fault Name

CALL

Serial communication transmission error
Communication is not established.

Cause

Possible Solution

Minor Fault

(H2-†† = 10)

Communication wiring is
faulty, there is a short circuit,
or improper connection.

Check for wiring errors:

• Correct the wiring
• Remove ground shorts and reconnect loose wires

YES

Programming error on the
master side.

Check communications at start-up and correct programming errors.

Communication circuitry is
damaged.

• Perform a self-diagnostics check
• Replace the drive if the fault continues to occur

EtherNet_IM_E_conditional.fm 48 ページ 2012年10月31日 水曜日 午後12時53分

This manual is related to the following products: