Si-p3 device data, Hsw/hiw, Task id – Yaskawa 1000 Series Drive Option - Profibus-DP Technical Manual User Manual
Page 30: Response id

8 Parameter Process Data Object Formats
30
YASKAWA ELECTRIC SIEP C730600 42B 1000-Series Option SI-P3 Technical Manual
HSW/HIW
Task ID
Response ID
SI-P3 Device Data
Bit
PPO Write
PPO Read
0 to 15
Setting Frequency (
±10000/100%)
Output Frequency or Motor speed (with PG) (
±10000/100%)
ID
Description
0
No action
1
Request parameter value
2
Change parameter value (word)
3
Change parameter value (double word)
6
Request parameter value from array
7
Change parameter value in array (word)
8
Change parameter value in array (double word)
9
Request number of array elements
ID
Description
0
No action
1
Transfer parameter value (word)
2
Transfer parameter value (double word)
4
Transfer parameter value (array word)
5
Transfer parameter value (array double word)
6
Transfer number of array element
7
Task cannot be executed (with error number)
Parameter
Setting Value
Note
GSD_Revision 3
GSD
file revision 3.0.
Vendor_Name “YASKAWA
ELECTRIC”
Model_Name
“PROFIBUS-DP INTERFACE CARD SI-P3”
Ident_Number 0x0ACF
FMS_supp
0
PROFIBUS-FMS not supported
Protocol_Ident 0
PROFIBUS-DP
supported
Station_Type
0
DP-Slave.
Slave_Family 3
Revision
“V1.0”
Device revision 1.0
Hardware_Release
“V1.0”
Hardware revision 1.0
Software_Release
“V1.0”
Software revision 1.0
Implementation_type
“DPC31”
DP protocol
Redundancy
0
Redundancy NOT supported
Repeater_Ctrl_Sig 2
Supported, TTL level
24V_Pins
0
No external 24 Volt input
Set_Slave_Add_supp = 1
1
Station address is set remotely
Auto_Baud_supp
1
Automatic baud rate select
9.6_supp
1
9600 Baud
19.2_supp
1
19.2 kBaud
45.45_supp
1
45.45 kBaud
93.75_supp
1
93.75 kBaud
187.5_supp
1
187.5 kBaud
500_supp
1
500 kBaud
1.5M_supp
1
1.5 MBaud
3M_supp
1
3 MBaud
6M_supp
1
6 MBaud
12M_supp
1
12 MBaud