beautypg.com

8 maintenance and cleaning, 1 cleaning the inverter, 2 checking the heat dissipation – SMA WB 5000A-11 Installation User Manual

Page 61: 1 cleaning the fans, Maintenance and cleaning, Cleaning the inverter, Checking the heat dissipation, Cleaning the fans

background image

SMA Solar Technology AG

Maintenance and Cleaning

Installation Manual

WB5A_6A-IA-IEN114540

61

8 Maintenance and Cleaning

8.1 Cleaning the Inverter

If the inverter is soiled and visibility of inverter operating data and operating modes is restricted, wipe
the enclosure lid, display and LEDs clean with a damp cloth. Do not use any caustic substances
(e.g., solvents, abrasives) for cleaning.

8.2 Checking the Heat Dissipation

8.2.1 Cleaning the Fans

If the fan guards are just clogged with loose dust, clean them with a vacuum cleaner. If you do not
achieve satisfactory results with a vacuum cleaner, dismantle the fans for cleaning.

Procedure

1. Disconnect the inverter from both the DC and AC sides as described in Section 7.2 "Opening

the Inverter" (page 57).

2. Wait for the fans to stop rotating.

Cleaning the Fan Guards

3. Remove the fan guards:

– Press both latches on the right edge of the fan

guard to the right using a screwdriver and
dislodge from the retainer.

– Carefully remove the fan guard.

4. Clean the fan guards with a soft brush, a paint

brush, a cloth or compressed air.

DANGER!
Danger to life due to high voltages in the inverter

• Stop the small wind turbine system and make sure that it cannot restart.
• Disconnect the inverter on the AC and DC sides.

This manual is related to the following products: