Technical Data

SMA Solar Technology AG

82

SC20_25_35-IEN094521

Installation Guide

Power Consumption

Sunny Central Control Interfaces

Standards

Protection rating and ambient conditions

Own consumption in operation (P

day

)

< 1000 W

Standby operating consumption (P

night

)

< approx. 70 W

External power supply / grid structure

230 V, 50 Hz / 60 Hz / TN-S, TT

External pre-fuse for internal power supply

B 16 A, 1 pole

Communication (NET Piggy-Back, optional)

Analog, ISDN, Ethernet

Analog Inputs

1 x PT 100, 2 x A

in

a)

a)

Terminal for an analog sensor provided by the customer in two-wire and four-wire version.

Overvoltage protection for analog inputs

Optional

Sunny String-Monitor connection (COM1)

RS485

PC interface (COM3)

RS232

Floating contact (external fault detector)

1

EMC

EN 61000-6-2, EN 61000-6-4

CE conformity

Yes

Protection rating as per EN 60529

IP 20

Permissible ambient temperatures

–20 °C ... +40 °C

Relative humidity, non-condensing

15 % ... 95 %

Maximum altitude above sea level

1000 m

Fresh air consumption

3300 m³/h