background image

Technical Data

SMA Solar Technology AG

44

SB11_12_17-IEN100132

Installation Guide

Efficiency curves

Sunny Boy 1200

Communication interfaces

SB 1100

SB 1200

SB 1700

RS485 (galvanically isolated)

optional

Radio

optional

Electronic Solar Switch (ESS)
Electrical lifetime (in the event of a short
circuit, with a nominal current of 30 A)

Min. 50 switching processes

Maximum switching current

30 A

Maximum switching voltage

800 V

Maximum PV power

approx. 10 kW

Protection rating when plugged

IP65

Protection rating when unplugged

IP21

Efficiency

SB1100

SB 1200

SB1700

Max. efficiency

η

max.

93 %

92.1 %

93.5 %

European efficiency

η

euro

91.6 %

90.7 %

91.8 %