SMA SB 1100 User Manual
Page 43
SMA Solar Technology AG
Technical Data
Installation Guide
SB11_12_17-IEN100132
43
General data
SB1100
SB 1200
SB1700
EC Declaration of Conformity
You can download the EC Declaration of Conformity
in the download area at www.SMA.de/en under
Certificates.
Dimensions (W x H x D)
440 mm x 339 mm x 214 mm (approx.)
Weight
approx. 22 kg
approx. 23 kg
approx. 25 kg
Protection rating according to DIN EN
60529
IP65
Climatic conditions according to DIN EN 50178:1998 - 04
Location of type C:
Class 4K4H
Extended temperature range: -25 °C ... +60 °C
Extended humidity range: 0 ... 100 %
Extended air pressure range: 79.5 kPa ... 106 kPa
Transport of type E:
Class 2K3
Temperature range -25 °C ... +70 °C
Operating temperature range
-25 °C ...+60 °C
Max. operating altitude
2000 m above mean sea level
Topology
Low frequency transformer
Protection class
I
Noise emission (typical)
≤ 39 dB(A)
≤ 41 dB(A)
≤ 46 dB(A)
Protective function DC side
All-pole disconnection unit on the DC input
side
Electronic Solar Switch, DC plug connector
Overvoltage protection
Thermally monitored varistors
Personal protection
Insulation monitoring (Riso > 1MOhm)
Pole Confusion Protection
Via short-circuit diode
Protective function AC side
Short Circuit Proof
Current control
All-pole disconnection unit grid side
Automatic disconnection device
(SMA Grid Guard 2.1),
double implementation