Commissioning the Sunny Boy

SMA Solar Technology AG

28

SB11_12_17-IEN100132

Installation Guide

PV overvoltage

1. Check DC voltage!

2. If the message occurs again, disconnect the Sunny Boy again and contact the Serviceline of

SMA Solar Technology (see section 13 "Contact" (page 47)).

NOTICE!
Excessive DC input voltage can destroy the Sunny Boy!

Immediately disconnect the Sunny Boy from the grid!

1. Turn off the line circuit breaker.
2. Remove the Electronic Solar Switch.
3. Disconnect the DC plug connectors.

Result

Action

☑ The DC voltage is higher than the

maximum input voltage.

• Contact the planner / installer of the PV

generator.

☑ The DC voltage is lower than the

maximum input voltage.

• Reconnect the Sunny Boy to the PV

generator as described in section
5.5 "Connecting the PV Generator (DC)"
(page 23).

!PV-Overvoltage!

!DISCONNECT DC!