11 technical data, Technical data – SMA SB 1100 User Manual
Page 42
Technical Data
SMA Solar Technology AG
42
SB11_12_17-IEN100132
Installation Guide
11 Technical Data
PV generator connection data
SB 1100
SB 1200
SB 1700
Max. input voltage
U
DC Max
400 V
a)
Input voltage, MPP range
U
PV
139 V ... 320 V 100 V ... 320 V 139 V ... 320 V
PV start voltage, adjustable
U
PV Start
180 V
120 V
180 V
Max. input current
I
PV Max
10 A
12.6 A
12.6 A
Max. input power
P
DC
1210 W
1320 W
1850 W
Voltage ripple
U
PP
< 10 % of the input voltage
Internal consumption during
operation
< 4 W
(standby)
< 4 W
(standby)
< 5 W
(standby)
a) The maximum open circuit voltage, which can occur at a cell temperature of 10 °C, may not exceed the maximum input
voltage.
Grid connection data
SB 1100
SB 1200
SB 1700
Nominal output power
P
AC nom
1000 W
1200 W
1550 W
Peak output power
P
AC max
1100 W
1200 W
1700 W
Nominal output current
I
AC nom
4.4 A
5.2 A
6.7 A
Max. output current
I
AC max
5.6 A
6.1 A
8.6 A
Max. fuse protection
16 A
Harmonic distortion of output current
(at K
Ugrid
< 2 %, P
AC
> 0.5 P
ACnom
)
K
IAC
< 3 %
Short Circuit Proof
grid-side via current regulation
Nominal operating voltage
U
AC nom
220 V / 230 V / 240 V
Voltage range
(extended operating range)
U
AC
180 V ... 260 V
Nominal operating frequency
f
AC nom
50 Hz / 60 Hz
Frequency range
(extended operating range)
f
AC
50 Hz: 45.5 Hz ... 54.5 Hz
60 Hz: 55.5 Hz ... 64.5 Hz
Power factor (at nominal output
power)
cos ϕ
1
Overvoltage category
III
Test voltage (DC)
1.7 kV (1 s routine testing / 5 s type testing)
Test surge voltage
4 kV (serial interface: 6 kV)
Internal consumption in night
operation
0.1 W