beautypg.com

Maintenance, Fan maintenance – Excalibur electronic P95-LP3 User Manual

Page 37

background image

Excalibur

®

P95-3 Zero Clearance Direct Vent Gas Fireplace

37

FAN MAINTENANCE

Unit must be grounded at all times. Do
not cut the ground terminal off under any
circumstances.

To Install the Fans

1) Shut the power off.

2) Open the bottom louver. Loosen the 2

screws holding the Burner ON/OFF switch
and bracket to the bottom louver and lift the
assembly out.

3) Remove the bottom louver by loosening the

2 hinge screws.

IMPORTANT: There are 2 fans in this fi replace.
Fan A (the right side fan) and Fan B (the
left side fan) are linked by a wire harness.
Please do not remove the wire harness when
installing the fans.

4) Move both fans and the wire harness

together to the front of the fi replace.

5) Insert Fan A in from the left sideways (see

diagram below). The easiest way to insert
Fan A is to put Fan B in front of the louver
opening. This ensures that there is suffi cient
length of wire between the 2 fans.

6) Take Fan A to the back above the mounting

studs. Then fl ip the fan and position it onto
the mounting studs.

7) Connect the ground wire from Fan A to the

Grounding Lug located on the left hand
side. See diagram 1.

8) Insert Fan B in from the front and position

it on top of the mounting studs on the left
side.

Diagram 1

Diagram 2

11) Attach the two control boxes to the bottom

unit base and tighten the 2 screws on the
left side and 1 screw on the right side.

Secure left side with 2 screws and right

side with one screw.

9) Connect the fan ground wire of Fan B and

the power cord ground wire to the grounding
lug. Refer to the wiring diagram.

10)

Slide the thermodisc/cover assembly

into the bracket clip on the underside of the
fi rebox. Check that no wire will touch the hot
surfaces. Diagram 2.

MAINTENANCE

Ensure that the fan blades do not rub against
the valve tubing.
See diagram 1.

12) Secure the fan wires and power cord by

attaching one of the adhesive backed
wire holder clips (Part #910-199) onto
the fi replace base. Use the second clip
to bundle up the wires approximately 4"
from the control box. Ensure that there is
no interference with the wires when the
louver is closed and that no wire will touch
the hot metal surfaces, fan blades or sharp
edges.

13) Plug the fan power cord into the rear end of

the receptacle box to provide the maximum
clearance from the louvers.

To Remove the Fans

1) Shut the power off.

2) Reverse

the

installation

instructions.

Note: The bearings are lubricated for life. Do
not lubricate them. Make sure you vacuum
the fan area on a regular basis.

IMPORTANT:

These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.

Slide Fan A in sideways

from the left.

Position Fan B on

mounting studs.

This manual is related to the following products: