Installation – Excalibur electronic P95-LP3 User Manual
Page 16
Excalibur
®
P95-3 Zero Clearance Direct Vent Gas Fireplace
16
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Three (3) 90
o
Elbows
INSTALLATION
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Option V
H + H1
A)
0' Min. 2' Max.
B)
1' Min. 3' Max.
C)
2' Min. 4' Max.
D)
3' Min. 5' Max.
E)
4' Min. 6' Max.
F)
5' Min. 7' Max.
G)
6' Min. 8' Max.
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
Option V
H V + V1 H + H1
A)
0' Min. 1' Max. 1' Min. 2' Max.
B)
1' Min. 2' Max. 3' Min. 3' Max.
C)
2' Min. 2' Max. 5' Min. 4' Max.
D)
3' Min. 2' Max. 7' Min. 5' Max.
E)
4' Min. 3 Max. 9' Min. 6' Max.
F)
5' Min. 4' Max. 10' Min. 7' Max.
G)
6' Min. 5' Max. 11' Min. 8' Max.
H)
7' Min. 6' Max. 12' Min. 9' Max.
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.