Installation – Excalibur electronic P95-LP3 User Manual
Page 19
Excalibur
®
P95-3 Zero Clearance Direct Vent Gas Fireplace
19
The P95-3 is approved for a maximum 40 ft. straight vertical, with Simpson
Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as
per the diagram.
The shaded area in the diagram shows all allowable combinations of straight
vertical and offset to vertical terminations with Simpson Dura-Vent Direct
Vent GS vent systems for Propane and Natural Gas. Maximum two 45
o
elbows allowed.
• Vent must be supported at offsets
• Firestops are required at each fl oor level and whenever passing
through a wall.
• Maintain clearances to combustibles as listed in the "Clearances,"
"Locating Your Gas Fireplace," "Combustible Mantels," "Unit Base
Stand-offs," "Framing and Finishing," "Facing Requirement," & "Hearth
Requirement" sections.
INSTALLATION
Please note that all vertical
measurements are taken from
the base of the unit excluding
risers or bottom stand-offs.