beautypg.com

Installation, Wiring diagrams, Natural gas – Excalibur electronic P95-LP3 User Manual

Page 32: Units and units, Equipped with dc spark boxes

background image

Excalibur

®

P95-3 Zero Clearance Direct Vent Gas Fireplace

32

WIRING DIAGRAMS

Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.

This heater does not require a 120V A.C. supply
for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.

(Do not cut the ground terminal off under
any circumstances.)

NOTE: Even if the fan is not purchased

with the unit, it is still a good idea to
bring power to the receptacle box
(provided with the unit) in case the
fan is installed at a later date.

CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring
errors can cause improper and
dangerous operation.

INSTALLATION

Ground

Green

Neutral

Live

Black

Red

Red

Fan Thermodisc

(normally open)

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan A

Fan B

Lockwasher

Fan

ground wire

Power cord

ground wire

Nut

#8 Ground Lug

(for mobile home)

Star

washer

Piezo

Ignitor

To Thermocouple IN

Pilot

Assembly

HI

LO

OFF

ON

P

IL

O

T

Gas

Pilot

Thermopile

Thermocouple

Electrode

Remote Transmitter

(Optional)

ON

OFF

Regency

Remote Receiver

or Thermostat

(Millivolt) (Optional)

Brown

Red

T-Stat

Black

White

"S.I.T" Valve

Burner ON

OFF

Thermostat

(To THTP)

(To TH)

White

Gas
In

For

NATURAL GAS

Units and Units

NOT

Equipped with DC Spark Boxes