beautypg.com

HEIDENHAIN TNC 640 (34059x-05) User Manual

Page 550

background image

Manual operation and setup

15.7 Using 3-D touch probes

15

550

TNC 640 | User's Manual

HEIDENHAIN Conversational Programming | 1/2015

Recording measured values from the touch-probe
cycles

The TNC must be specially prepared by the machine
tool builder for use of this function. Refer to your
machine manual.

After executing any selected touch probe cycle, the TNC displays
the soft key

WRITE LOG TO FILE. If you press this soft key, the

TNC will record the current values determined in the active touch
probe cycle.

If you store the measuring results, the TNC creates the text
file TCHPRMAN.TXT. If you have not defined a path in the
machine parameter

fn16DefaultPath, the TNC will store the

TCHPRMAN.TXT and TCHPRMAN.html files in the main directory
TNC:\.

When you press the

WRITE LOG TO FILE soft key,

the TCHPRMAN.TXT file must not be active in the
Programming mode of operation. The TNC will
otherwise display an error message.

The TNC writes the measured values to the
TCHPRMAN.TXT or TCHPRMAN.html file. If you
execute several touch probe cycles in succession
and want to store the resulting measured data,
you must make a backup of the contents stored in
TCHPRMAN.TXT between the individual cycles by
copying or renaming the file.

Format and content of the TCHPRMAN.TXT file are
preset by the machine tool builder.