Sorting and tolerance checking – HEIDENHAIN NPD 281 v.3 User Manual

Page 12

background image

12

gut

Nacharbeit

Ausschu§˜

Sorting and Tolerance Checking

In the sorting and tolerance checking mode, the display unit
compares the displayed value with the programmed upper
and lower sorting limits. The sorting and tolerance checking
mode is enabled and disabled with operating parameter P17.

Entering sorting limits

Sorting limits are entered in operating parameters P18 and
P19 (see “Operating Parameters”).

Sorting signals

The indicators and switching outputs at D-sub connection
EXT (X41, see page 34) sort the display value into one of three
classes.

Display

Meaning

=

Measured value is within sorting limits

<

Measured value is smaller than lower sorting limit

>

Measured value is greater than upper sorting limit

Operating parameters for sorting and tolerance checking

Sorting ON/OFF

Lower sorting limit

Upper sorting limit

Example: Upper sorting limit = 26.02 mm

Lower sorting limit = 26.00 mm

Part 1

Part 2

Part 3

Sorting and Tolerance Checking

Accept

Rework

Reject