87

MAINTENANCE

Spark Arrestor

Use the following procedure to periodically purge accumulated carbon

from the exhaust pipe.
1. Remove the arrestor clean-out

plugs located on the bottom of the

muffler.

2. Place the transmission in neutral.
3. Engage the park brake.
4. Start the engine.
5. Purge accumulated carbon from

the system by momentarily rev-

ving the engine several times.

6. If carbon is expelled, cover or

plug the exhaust outlet and rap on

the pipe around the clean-out plugs while revving the engine several

more times.

7. If particles are still suspected to be in the muffler, elevate the rear of

the vehicle one foot higher than the front. Block the wheels.

8. Repeat steps 5 and 6 until no more particles are expelled when the

engine is revved.

9. Stop the engine. Allow the arrestor to cool.
10. Reinstall the arrestor plugs and remove the outlet cover or plug.

Clean-Out

Plugs

Exhaust

Outlet