beautypg.com

Grass Valley Thunder 80 v.1.0 User Manual

Page 44

background image

28

System Implementation

F - Auxilliary Power Input

The auxiliary power input is connected to +10 to +30 VDC via a KPJX-4S-S connector.

G - Optical connection Panels

A variety of optical fiber connector plates are available for the Thunder frame, in order to
support most available fiber plugs:

A

B

C

D

E

F

Fig. 3-2: Fiber Connector Plates

A - ST single

B - ST2 - Dual STs for redundant input/output

C - ST4

D - MX

E - OpticalCON Duo

F - OpticalCON quad

Laser sources are available at 1310 nm, 1550 nm WDM, and at the various CWDM
wavelengths.

H - AC Power input

100-240 VAC mains, 50-60 Hz.