PVS3000 & PVS 3500 Installation Guide
31
Set up PFR700 network settings
This procedure explains how to modify factory default PFR700 network and SNMP
settings for monitoring with NetCentral Lite or NetCentral Manager. This step is not
required for PFC500 RAID storage systems.
NOTE: Disregard this step if you are connecting one Profile XP Platform and
PFC500 RAID storage system to a network using factory default network settings.
Proceed to “Start NetCentral Lite monitoring software” on page 33.
Refer to the Profile XP Service Manual for information on using NetCentral Lite.
Configuring PFR 700 network and SNMP settings
Network and SNMP settings are set and stored on the LAN card. Therefore the PFR700
RAID chassis, including its one or two RAID controllers, is a single networked device.
This is different than other PFR series RAID devices in which each controller is a
networked device.
You can use the GVG Disk Utility to configure the following settings for the PFR700
RAID chassis:
• IP address
• Subnet mask
• Gateway Address
• SNMP trap destinations
To configure these settings, do the following:
1. In the GVG Disk Utility, right-click the icon for a PFR700 controller and select
Set
Network Properties
. The Controller Network Settings dialog box opens.
1
5
1
7