Grass Valley Kayenne Installation Planning Guide Aug 30 2011 User Manual
Page 72

72
KAYENNE — Installation Planning Guide
Appendix A — Specifications
Table 9. Network Connections
Type of connection
10/100/1000 Base T
Protocol
TCP(UDP)/IP, Auto speed detection. Auto crossover cable configuration.
Cable and connectors
CAT5 UTP, RJ45 connectors;
Max. Cable Length
100m / 300ft
Note
The Video Processor Frame and the PCU Frame each have an internal Ethernet switch. The VP Frame has four
available external ports on its switch, two of which are to be used with each PCU (two PCUs maximum). The PCU
has six available external ports on its internal switch, and one additional port dedicated for Control Panel use.
When a PCU is attached to the VP Frame, five PCU ports remain available for additional network connections.
Table 10. PCU Interconnects
Control Panel - PCU Connections
Cable and connectors
Custom 7 Pin D style
Number Required
1 for each Control Panel Stripe, Local Aux Stripe, and Satellite Panel
Max. Interconnect Cable Length
15 m / 50 ft. (7.5 m / 25 ft. cable length also available)
Cable Weight
15 m / 50 ft.
1.3 kg (2.9 lbs)
7.5 m / 25 ft.
0.7 kg (1.6 lbs.)
Touch Screen Menu Panel - PCU Connection
Cable and connectors
Custom 17 Pin D style
Number Required
1 for each Menu Panel (2 maximum)
Max. Interconnect Cable Length
15m / 50ft (7.5m / 25ft cable length also available)
Cable Weight
15 m / 50 ft.
1.6 kg (3.7 lbs)
7.5 m / 25 ft.
0.9 kg (2.0 lbs.)
Table 11. Power
4-RU Video Processor Frame
Line voltage
100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.
Line frequency
50/60Hz +/- 5%
Power consumption
max. 400W
Leakage current
< 2.5 mA
8-RU Video Processor Frame
Line voltage
100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.
Line frequency
50/60Hz +/- 5%
Power consumption
max. 1000W
Leakage current
< 2.5 mA
Panel Control Unit (required for Control Panel and Touch Screen Menu Panel Operation)
Line voltage
100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.
Line frequency
50/60Hz +/- 5%
Power consumption
max. 500W
Leakage current
< 2.5 mA