beautypg.com

Grass Valley Kayenne Installation Planning Guide Aug 30 2011 User Manual

Page 72

background image

72

KAYENNE — Installation Planning Guide

Appendix A — Specifications

Table 9. Network Connections

Type of connection

10/100/1000 Base T

Protocol

TCP(UDP)/IP, Auto speed detection. Auto crossover cable configuration.

Cable and connectors

CAT5 UTP, RJ45 connectors;

Max. Cable Length

100m / 300ft

Note

The Video Processor Frame and the PCU Frame each have an internal Ethernet switch. The VP Frame has four
available external ports on its switch, two of which are to be used with each PCU (two PCUs maximum). The PCU
has six available external ports on its internal switch, and one additional port dedicated for Control Panel use.
When a PCU is attached to the VP Frame, five PCU ports remain available for additional network connections.

Table 10. PCU Interconnects

Control Panel - PCU Connections

Cable and connectors

Custom 7 Pin D style

Number Required

1 for each Control Panel Stripe, Local Aux Stripe, and Satellite Panel

Max. Interconnect Cable Length

15 m / 50 ft. (7.5 m / 25 ft. cable length also available)

Cable Weight

15 m / 50 ft.

1.3 kg (2.9 lbs)

7.5 m / 25 ft.

0.7 kg (1.6 lbs.)

Touch Screen Menu Panel - PCU Connection

Cable and connectors

Custom 17 Pin D style

Number Required

1 for each Menu Panel (2 maximum)

Max. Interconnect Cable Length

15m / 50ft (7.5m / 25ft cable length also available)

Cable Weight

15 m / 50 ft.

1.6 kg (3.7 lbs)

7.5 m / 25 ft.

0.9 kg (2.0 lbs.)

Table 11. Power

4-RU Video Processor Frame

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 400W

Leakage current

< 2.5 mA

8-RU Video Processor Frame

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 1000W

Leakage current

< 2.5 mA

Panel Control Unit (required for Control Panel and Touch Screen Menu Panel Operation)

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 500W

Leakage current

< 2.5 mA