Ru frame power supplies – Grass Valley Kayenne Installation Planning Guide Aug 30 2011 User Manual
Page 44

44
KAYENNE — Installation Planning Guide
Section 3 — Kayenne Frames
Figure 45. Kayenne 8-RU Frame, Backplane View
8-RU Frame Power Supplies
The 8-RU Kayenne Video Processor frame has two power supplies stan-
dard. A minimum of two supplies are needed for 8-RU frame operation.
An additional power supply is available as an option for redundancy. It
slides into the extra power supply slot in the chassis. When equipped with
the redundant power supply option, the frame will continue to operate
without interruption should a single power supply fail.
8623266_35
(Not used with Kayenne)
100-240V AC
Power Supply 1
Redundant AC
Power Supply 3
(option)
100-240V AC
Power Supply 2
Grounding Lug
GPI In/Out 9-16
Tally 25-48
(2 M/E only)
GPI In/Out 1-8
Tally 1-24
HD Reference In
Tri Level Sync
Video Out
1 M/E: 1-12
2 M/E: 1-24
3 M/E: 1-36
4 M/E: 1-48
Video In
1 M/E: 1-24
2 M/E: 1-48
3 M/E: 1-72
4 M/E: 1-96
SD Reference In
LAN
(Internal Switch
with 4 Ports)
RS422/485
Serial Ports
(8)
GPI In/Out 25-32
Tally 73-96
(4 M/E only)
GPI In/Out 17-24
Tally 49-72
(3 M/E only)