Operation

Alarm Configuration Panel

Status/Name

The Status/Name column lists all the alarms reported by this KMV-3901/3911 multiviewer.
Next to each alarm name, an icon shows the alarm’s current status.

Card LED, Overall alarm and GSM contribution

The Card LED, Overall alarm and GSM contribution columns contain lists that allow you to
set the level of contribution of each individual alarm to the alarm named in the column
heading.

Card LED

This column allows you to configure the behavior of the KMV-3901/3911’s card-
edge status LED.

Overall alarm

This column allows you to configure the contribution of each individual alarm
to the overall alarm associated with this card. Indicators for the overall alarm
appear in the upper left corner of the control panel windows, and at the
bottom of the Status/Name column.

GSM
contribution

This column allows you to configure the contribution of each individual alarm
to the GSM alarm status associated with this card. The GSM is a dynamic
register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for the GSM contribution are related to the
overall alarm contribution:
• If the overall alarm contribution is set to Disabled, then the GSM alarm

contribution can be set to any available value.

• If the overall alarm contribution is set to any level other than disabled, then

the GSM contribution follows the overall alarm.

Alternatively, select the Overall alarm and GSM contribution follow card LED
check box, to have the same contribution in all three contexts for the
corresponding individual alarm.

Note:

N/A means the alarm is not user-configurable.

Overall

alarm

indicators