Chassis fan, Disk modules, Compactflash boot media – Grass Valley K2 Solo 3G Client Service Manual v.9.0 User Manual
Page 30: Power supply module, Codec module

Chassis fan
The chassis fan is mounted in the fan bracket. It provides cooling to the unit. It is mounted in the
front of the unit, behind the front bezel.
Related Topics
on page 91
Disk modules
There are slots for disk modules in the K2 Solo 3G system. The slots are located behind the front
bezel assembly in the front of the chassis. Each slot can contain one disk module, and each module
contains one hard drive. A K2 Solo 3G system contains 2 disk modules. Disk modules plug into the
drive cable assembly.
Data is written or “striped” across the disks in a continuous fashion, which makes the disks a “stripe
group”. This stripe group appears as the V: drive to the Windows operating system. The V: drive
stores media. It also stores media file system, database, and configuration information.
Disks are configured as RAID 0, so you can not remove and replace a disk module while the K2
Solo Media Server is operational. If a disk fails, you lose all media.
Related Topics
on page 93
CompactFlash boot media
The CompactFlash boot media contains the system drive, also known as the C: drive. The C: drive
contains application and operating system files. The CompactFlash media is hosted by the front
interconnect board.
Related Topics
CompactFlash boot media removal K2 Solo
on page 91
Power supply module
The K2 Solo 3G system has one power supply. You can not remove and replace the power supply
while the K2 Solo 3G system is operational. The power supply has a fan with automatic speed
control. The power supply has protection for over voltage, over current, and short circuits.
Related Topics
on page 99
Codec module
The K2 Solo 3G Media Server has one codec module. The codec module hosts two media input/output
channels. The codec module is oriented horizontally across the rear of the K2 Solo 3G Media Server
30
K2 Solo 3G Service Manual
06 November 2012
Product description