beautypg.com

Fiber, Settings web page – Grass Valley 8949MDA-CFR v.1.1.X User Manual

Page 30

background image

30

8949MDA-CFR/-SFR—Instruction Manual

Remote Configuration

Settings Web Page

Use
this
link

The Settings web page for 8949MDA-CFR (

Figure 13 on page 31

) and

8949MDA-SFR (

Figure 14 on page 32

) provides a reporting of signal control

for the DA output. This page gives the model, the description and the frame
location and provides controls to perform input configuration.

The parameters for configuration of a 8949MDA module are explained
below:

The

Routing Mode

area will be different, depending on the presence and

type of fiber optic submodules. This area shows the available inputs.
Only one input can be selected.

Coax In 1

– Selection of J9 BNC coax input.

Optic 1 or/and 2

– Selection of the available optical input.

Optic Outputs

– when fiber optic outputs are available from the installed

fiber optic submodule, select

Enable

or

Disable

. (Not applicable when a

Dual Receiver (1310NM-DRL is installed).

Input Reporting

– choose between

Enable

or

Disable

. The

Enable

parameter

sends alarms to the 8900NET module on the input signals (presence of
signal). The color of arrows on the module Status web page will be
automatically changed.

The

Disable

parameter will change the color of arrows on the Status web

page to gray to show they are not being monitored or reported to upper
level control devices.

Input Format

– selection of the input format transported on the HD-SDI or

SD-SDI signal. Refer to the

Table 2 on page 13

.

Carrier Detect

– indicates the presence of valid input signal.

Locked Rate

– this value is linked to the input bitstream rate detected.

Video Format

– this value reports the input format detected.

Monitoring Format

– this value indicates the downscaled output format.

Composite Color Bar

– this parameter allows the selection of a composite

color bar test pattern on the downscaled outputs.

Composite Setup

– this parameter is shown if the

Monitoring Format

is

480i/59.94. Configure as

Setup

or

No Setup

on the composite outputs as

shown in

Figure 13 on page 31

.

This manual is related to the following products: