Module placement in the geckoflex frame, Module installation precautions – Grass Valley 8949MDA-CFR v.1.1.X User Manual
Page 14

14
8949MDA-CFR/-SFR—Instruction Manual
Installation
Module Placement in the GeckoFlex Frame
There are ten rear and front slot locations in the 2 RU frame to accommo-
date either video or audio modules of all types. The 8949MDA-CFR or
8949MDA-SFR module can be plugged into any one of the GeckoFlex
frame slots. Both modules require the 8900WFR-R rear module in the cor-
responding rear slot.
Module Installation Precautions
Please read and follow the precautions listed below before installing the
front and rear modules and any fiber optic option submodules:
•
Use standard anti-static procedures during installation. As modules
can be installed or removed when the GeckoFlex frame is powered up,
before removing the cover, please use an anti-static bracelet tied to a
metal part of the frame.
•
Install the rear module first, then the front module, then the optical sub-
module option (if used).
•
When installing or removing a rear module, loosen or tighten the
screws holding the retainer clips to the frame manually with the
retainer clip tool provided inside the front cover of the frame or use a
2 mm (5/64”) hex screwdriver. Please do not use an electric screw-
driver.
Note
On newer 751- version GeckoFlex frames, a Rear Retainer Clip removal tool
and 2 extra retainer clips and screws for installing them are provided on the
inside of the frame cover.
•
Make every effort to leave the screws holding the retainer clips in place
(do not remove them completely). They are very small and can easily
drop into other equipment causing a shorting hazard. (Two turns of the
screw should be enough to loosen the screws, 3 turns or more will
remove it.)
•
When installing a rear module, tighten the screws on the retainer clips
just until snug. Do not apply more force than is necessary to seat the
rear module.
•
If using a fiber optic submodule, handle it carefully, use anti-static pre-
cautions, and read the
Fiber Optic Cleaning Requirement on page 18
before cabling.