8900NET Instruction Manual

33

Using the 8900NET GUI

Legacy Module Support

Installation of 8500 and 8800 modules shipped prior to November 15, 1999
will cause interruption of the 8900TFN and 8900-FFN frame communica-
tion bus. Modules shipped after this date have pins removed in the rear
connector to provide compatibility. Compatible modules can be identified
by the absence of connector pins 10 and 50 (see

Figure 15

). Incompatible

legacy modules can be returned to Grass Valley for upgrade to the new con-
nector.

Note

If an unmodified legacy module is installed in the frame, the frame commu-
nication bus will be interrupted and all module icons in the frame status
display will be red. This problem occurs with legacy modules only and does
not occur with Gecko 8900 Series and Gecko Flex modules.

Figure 15. Modified Legacy Module Connector

Pin 10

Pin 50

0612-18

Pin 2

Top of Module

Pin 50

Removed

Typical