beautypg.com

8900net module alarm dip switches – Grass Valley 8900NET v.4.0.0 User Manual

Page 20

background image

20

8900NET Instruction Manual

Status Monitoring and Reporting

8900NET Module Alarm DIP Switches

Two eight-position DIP switches (S1 and S2) enable or disable the overall
status reporting of the frame, including Frame Alarm and SNMP moni-
toring. The current status of these settings is reported on the Frame Alarm
Reporting (

page 37

) and SNMP Reporting (

page 39

) frame web pages.

Refer to

Figure 11 on page 17

for the location of S1 and S2 on the 8900NET

module and

Figure 12

and

Table 2

for the possible settings. A settings table

is also silk-screened on the bottom of the module. Disabling (or filtering) of
fault reports can sometimes be useful in isolating problems in the frame.

Figure 12. Alarm Reporting DIP switches

Note

Disabled faults are still detected by the network GUI but LEDs will be inactive.

Table 2. 8900NET Module DIP Switches

S1

Segmen

t

Left Position (open)

Right Position (closed)

1

PS1 Fault Reporting Enabled

PS1 Fault Reporting Disabled

2

PS2 Fault Reporting Enabled

PS2 Fault Reporting Disabled

3

(Not used) Over Temp reporting is always enabled locally and through SNMP

4

Fan Fault Reporting Enabled

Fan Fault Reporting Disabled

5

Module Fault Reporting Enabled

Module Fault Reporting Disabled

6

Frame Bus Error Reporting Enabled

Frame Bus Error Reporting Disabled

7

Fan Speed Controlled by Temperature

Fan Speed Fixed at Maximum

8

Network Module Control Enabled (remote control via GUI is
enabled)

Network Module GUI is placed in read only mode

S2

Segmen

t

Left Position (open)

Right Position (closed)

1

Status Enabled (enabled alarms are reported over SNMP)

SNMP Reporting is disabled except for Over Temp alarm

2

IP Address (not currently supported)

3

Frame Control Enabled (remote control via GUI is enabled)

GUI for the frame and all modules within is placed in read only mode

4 – 8

(Currently Not Used)

12345678

12345678

S2

S1

Power Supply #1
Power Supply #2

Temperature

Fan

Module

Frame Bus

Fan Speed

NM Control

Status

8900NET

IP Address

Frame Control

Remote

Override

LED

0612_28