Installation, Unpacking, Module/software installation – Grass Valley 7600REF User Manual
Page 19: Rack mounting

7600 SD/HD/MHD-REF — Instruction Manual
19
Installation
Installation
Follow the instructions below to unpack, install, and cable the 7600REF
frame.
Unpacking
Carefully unpack the unit from its packing box and check for signs of
damage. Check the contents of the box against the packing list and your
original order to ensure that you have received the correct parts.
In the event the unit has been damaged or does not match your order,
contact the Thomson Grass Valley Sales office listed on Contacting Grass
Valley
Module/Software Installation
All hardware modules are installed at the factory and shipped inside the
unit. Module functionality included in the model configuration depends
on the model type (see
). Any software function-
ality included with the model is already installed and enabled.
Rack Mounting
The 1 RU rack frame has integral rack mounting ears on the frame front
cover for direct mounting into a standard 19 inch rack. Carefully place the
unit in your rack and firmly attach it to the rack using four standard rack
screws (not provided).
CAUTION This unit has air intakes on one side of the unit and fan-assisted exhaust vents
on the other side of the unit. Ensure that these have an unobstructed air flow,
otherwise the unit will overheat. Pay particular attention to ensure that any
rack wiring or cable trays do not obstruct the vent. 60 mm (2.36 in.) of clear
space should be allowed between the vents and any potential obstruction.