Installation, Module placement in the kameleon frame – Grass Valley 2000NET v3.2.2 User Manual

Page 9

background image

2000NET Instruction Manual

9

Installation

Installation

This section describes placing the module in the 2000 Series Kameleon
frame and cabling the communications ports. Procedures for power-up,
DIP switch settings, and network configuration of the module are
described in following sections.

Module Placement in the Kameleon Frame

There are two rows of six front media module slots in the frame to accom-
modate either analog or digital media modules. Between these rows are
slots for the 2000NET and Frame Reference modules. Refer to

Figure 3

.

The three slots on the right side of the frame are allocated for the power
supply sleds and the optional fan module. For additional information con-
cerning the Power Supply module, refer to the

2000 Series Frame Instruction

Manual

.

Slot number 13 (top middle) is allocated for the 2000NET module.

Figure 3. 2000T3 Frame Front Module Locations

Note

The 2000NET module can be plugged in and removed from a 2000 Series
Kameleon frame with power on. When power is applied to the module, LED
indicators reflect the initialization process (see

Power Up

on page 17

).

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(15)

(13)

(1)

Slot (20)

8046-06

Network Interface Module

Frame Reference Slot

Front Media Modules
Slots 1-12