Installation, Module placement in the kameleon frame – Grass Valley 2000NET v3.2.2 User Manual
Page 9
2000NET Instruction Manual
9
Installation
Installation
This section describes placing the module in the 2000 Series Kameleon
frame and cabling the communications ports. Procedures for power-up,
DIP switch settings, and network configuration of the module are
described in following sections.
Module Placement in the Kameleon Frame
There are two rows of six front media module slots in the frame to accom-
modate either analog or digital media modules. Between these rows are
slots for the 2000NET and Frame Reference modules. Refer to
The three slots on the right side of the frame are allocated for the power
supply sleds and the optional fan module. For additional information con-
cerning the Power Supply module, refer to the
2000 Series Frame Instruction
Manual
.
Slot number 13 (top middle) is allocated for the 2000NET module.
Figure 3. 2000T3 Frame Front Module Locations
Note
The 2000NET module can be plugged in and removed from a 2000 Series
Kameleon frame with power on. When power is applied to the module, LED
indicators reflect the initialization process (see
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(15)
(13)
(1)
Slot (20)
8046-06
Network Interface Module
Frame Reference Slot
Front Media Modules
Slots 1-12