Installation

Cabling

This section describes physical connections, the connectors and cables,
used for network communications. Setup procedures for each type of con-
nection are described in

Establishing Frame Network Identity

on page 22

.

Control and monitoring connectors on the 2000T3 frame are illustrated in

Figure 5

.

Note

The cables and adapters illustrated below for connection to a PC are available
from Grass Valley as part of cable kit model 8900CAB. The standard Ethernet
cable is not included.

Figure 5. 2000NET Input/Output Connectors

Frame Health Alarm Connection

The frame health alarm connection provides a relay closure that will act as
an alarm trigger for a user-supplied alarm circuit. The relay is accessed
through connector J103 SER3/GPI. Complete details for cabling the Frame
Health Alarm are given in the Installation section of the 2000 Frame
Instruction Manual.

The Frame Health Alarm responds to conditions enabled on the 2000NET
Network Interface module with DIP switches S1 and S2 as given in

Table 3

on page 20

. This information from the module is also available over the

network to an SNMP monitoring system as described in

SNMP Monitoring

on page 20

.

Network ethernet

RJ-45 connector

(J104 Main)

8046-08

Configuration

serial port connector

(J101 Config)

Frame Health

DB9 connector

(J103 GPI)