Cabling, Frame health alarm connection – Grass Valley 2000NET v3.2.2 User Manual
Page 11

2000NET Instruction Manual
11
Installation
Cabling
This section describes physical connections, the connectors and cables,
used for network communications. Setup procedures for each type of con-
nection are described in
Establishing Frame Network Identity
.
Control and monitoring connectors on the 2000T3 frame are illustrated in
Note
The cables and adapters illustrated below for connection to a PC are available
from Grass Valley as part of cable kit model 8900CAB. The standard Ethernet
cable is not included.
Figure 5. 2000NET Input/Output Connectors
Frame Health Alarm Connection
The frame health alarm connection provides a relay closure that will act as
an alarm trigger for a user-supplied alarm circuit. The relay is accessed
through connector J103 SER3/GPI. Complete details for cabling the Frame
Health Alarm are given in the Installation section of the 2000 Frame
Instruction Manual.
The Frame Health Alarm responds to conditions enabled on the 2000NET
Network Interface module with DIP switches S1 and S2 as given in
. This information from the module is also available over the
network to an SNMP monitoring system as described in
.
Network ethernet
RJ-45 connector
(J104 Main)
8046-08
Configuration
serial port connector
(J101 Config)
Frame Health
DB9 connector
(J103 GPI)