beautypg.com

Rebooting the module – Grass Valley 2000NET v3.2.2 User Manual

Page 18

background image

18

2000NET Instruction Manual

Power Up

The module LEDs and their possible status and indicated conditions are
shown in

Table 2

.

Rebooting the Module

If you need to reboot the 2000NET module, either remove and replace the
module in the slot or use the GUI to access the Configuration or Network
pages. Both pages have a

Reboot

button (see

2000NET Module Interface

on

page 33

).

Table 2. Indicator LEDs and Conditions Indicated

LED

LED State

Condition

POWER OK

(green)

Off

Power is off or on-board regulator has failed

On continuously

Module is powered

ETHER(NET)

(yellow)

Active

Indicates communication taking place on the Ethernet bus

LNK

(green)

Active

Indicates active link established with another device on the Ethernet bus

PS1

(red)

Off

Power supply 1 is operating normally or is not installed

On continuously

Power supply 1 is present and reporting output not within specified voltage range

PS2

(red)

Off

Power supply 2 is operating normally or is not installed

On continuously

Power supply 2 is present and reporting output not within specified voltage range

PS3

(red)

Off

Power supply 3 is operating normally or is not installed

On continuously

Power supply 3 is present and reporting output not within specified voltage range

PS4

(red)

Off

Power supply 4 is operating normally or is not installed

On continuously

Power supply 4 is present and reporting output not within specified voltage range

TEMP

(red)

Off

2000NET sensors reading temperature within specified parameters

On continuously

Over-temperature condition detected in frame

FP (Front Panel)

(red)

Off

Currently not used

On

REM OVR

(yellow)

Off

Module settings match those set onboard by switches and jumpers

On

One or more settings have been overridden by remote control system (see

Table 3

on page 20

)

COMM

(yellow)

Active

Indicates module is polling the devices on the internal frame communication bus

FAN

(red)

Off

All fans in the frame are working properly

On continuously

At least one fan in the frame is not rotating at its specified rate

FB (Frame Bus)

(red)

Off

Network module is communicating with modules on the Frame Bus

On

Internal Frame Bus communication failure

MOD
(red)

Off

None of the media or center communication/sync modules is reporting a fault

On continuously

At least one of the media or center communication/sync modules is reporting a fault

NM (Net Module)

(red)

Off

Network Module is working properly

On continuously

Network Module has detected an internal fault and is not functioning