Grass Valley 2000NET v3.2.2 User Manual
Page 30

30
2000NET Instruction Manual
Using the 2000NET GUI
Locate Frame
Select the
Flash
radio button in the
Locate Frame
function to flash the front
LEDs on the 2000NET module to help locate the 2000 frame.
Save/Load Frame Configuration File
You may save a frame configuration to a file by clicking on the
Save To
button. A frame configuration is saved to a default file (FrameConfig-
Data.mcm) and the name cannot currently be changed. Follow the file
download instructions for saving the file. This file can be recalled on this or
any other networked 2000 frame to create a duplicate configuration.
Use the
Browse
button to locate a saved frame configuration file or enter a
path and file name into the display. Select the
Load
button to load the
selected configuration to the frame.
Frame Identification
Enter any name, an index number (for SNMP reporting), and a location
name to identify a frame. You may also use the factory default frame name
or location by selecting either
Default
button.
Frame SNMP Trap Reports
The Frame Configuration web page allows you to enable the following
SNMP slot reports shown in
:
•
Frame Bus Status (Alarm)
•
Fan Status (Alarm)