beautypg.com

Grass Valley 2010RDA User Manual

Page 19

background image

2010/2011RDA Instruction Manual

13

Remote Configuration and Monitoring

The

INPUT STATUS OUTPUT MODE

display (

Figure 12

) provides the following

status reporting items for the module:

MODE

indicates whether the on-board jumper is configured for

SINGLE

,

DUAL

or

QUAD

output mode. (Refer to

Set Operating Mode

on page 10

.)

REAR MODULE ID

indicates whether the 2000PRM-D (

PRM-D

) or COAX

PRM (

PRM-COAX

) passive rear module is installed. (Refer to

2000PRM-D

Passive Rear Module

on page 6

or

2010RDA COAX PRM Passive Rear

Module

on page 5

.)

INPUT IMPEDANCE

indicates the input impedance of the passive rear

module installed as

75 OHM

(COAX PRM) or

110 OHM

(2000PRM-D).

CHANNEL LOCK

indicates whether each channel is

LOCKED

(valid AES ref-

erence signal is present and module is locked to it) or

UNLOCKED

(module does not detect a valid AES reference signal).

SAMPLE RATE

indicates the current input sample rate being detected by

each channel as one of the following:

OUT OF RANGE

,

32K

,

44.1K

,

48K, 88.2K

or

96K

.

Figure 12. 2010/2011RDA Input Status/Output Mode Display

D

Use
This
Link

Ouput mode

Channel lock status

Type of rear
module installed

Input impedance

Sample rate status

2010RDA Module
installed

2011RDA Module
with PRM-D passive
rear module installed
and set to Quad mode

This manual is related to the following products: