Configuration and monitoring, Local onboard module configuration, Set operating mode – Grass Valley 2010RDA User Manual
Page 16: Of operation. refer to

10
2010/2011RDA Instruction Manual
2010/2011RDA Dual/Quad AES/EBU Reclocking DA
Configuration and Monitoring
Configuring the 2010/2011RDA consists of setting the operating mode to
single, dual or quad input/output with an on-board jumper.
Local Onboard Module Configuration
The 2010/2011RDA module is configured locally using the jumper shown
in
. The CONF LED indicates status of the configuration process.
Figure 9. Module Configuration Switches and LEDs
Set Operating Mode
Set jumper JP5 for one of the following operating modes:
Single (pins 1/2)
■
1 input by 8 outputs (COAX PRM), or
■
1 input by 16 outputs (2000PRM-D).
Dual (pins 3/4)
■
2 inputs by 4 outputs (COAX PRM), or
■
2 inputs by 8 outputs (2000PRM-D).
Quad (pins 5/6)
■
4 inputs by 4 outputs (2011RDA-110 module only)
8068_03
LOCK1
FAUL
T
COMM
CONF
PWR
LOCK2
LOCK3
LOCK4
JP5
SINGLE
JP5
2010RDA DUAL AES/EBU RECLOCKING DA
DUAL
QUAD
2011RDA QUAD
Configuration LED
1
6