2010/2011RDA Instruction Manual

5

Installation

Cabling

All cabling to the modules is done on the corresponding passive rear
module at the back of the 2000 frame. There are two versions of passive rear
modules available for the 2010RDA, the COAX PRM with 75

BNC I/O

(

Figure 5

) and the 2000PRM-D with 110

D-connector I/O (

Figure 6

). The

2011RDA-110 uses only the 2000PRM-D passive rear module.

Refer to the instructions that follow for cabling either the COAX PRM or
2000PRM-D passive rear modules for single, dual or quad mode.

2010RDA COAX PRM Passive Rear Module

The COAX PRM module provides ten 75

(unbalanced) BNC connectors

for single or dual operation with the 2010RDA. Refer to

Figure 5

for an

illustration of the COAX PRM passive rear module.

The module must be jumpered during configuration for the desired mode
of operation. Refer to

Set Operating Mode

on page 10

.

Figure 5. COAX PRM Passive Rear Module

Refer to

Table 1

for single and dual channel cabling.

Note

At the back of this manual are overlay cards that can be placed over the BNC
connectors to identify specific single or dual connector function.

Table 1. COAX PRM Cabling Pinouts

Connector

Single Mode

Dual Mode

J1

Ch 1 In

Ch 1 In

J2

Ch 1 Out 1

Ch 1 Out 1

J3

Ch 1 Out 2

Ch 1 Out 2

J4

Ch 1 Out 3

Ch 1 Out 3

J5

Ch 1 Out 4

Ch 1 Out 4

8068_06

COAX

PRM

J6

J7

J8

J9

J10

J5

J3

J4

J2

J1

Single Mode

Dual Mode

Out 1 – 4

CH1 Out 1 – 4

CH2 Out 1 – 4

In 1

CH1 In

CH2 In

Out 4 – 8