beautypg.com

H3C Technologies H3C Intelligent Management Center User Manual

Page 11

background image

7

Figure 7 System Settings

The following describes the system settings:

File Server Parameters: Set the file server status, enabled or disabled. In a NAT environment, you
can enable the file server function to perform device backup and deployment operations. When the

file server is enabled, the IP address of the file server must be configured.

Default Polling Interval: Interval for iMC BIMS to poll the connection status of devices. If any device
is found unreachable, iMC BIMS changes the status of the device.

Periodic Inform Interval: Default interval for the device to access iMC BIMS. The device actively
reports its current status when accessing iMC BIMS.

Device Access Parameters: Username and password used by iMC BIMS to connect to a CPE device.
iMC BIMS can actively connect to the device only if the username and password are the same as

those for the CPE to access iMC BIMS. A newly added CPE device needs to use the username and

password when accessing iMC BIMS.

CPE Device Adding Policy: Specifies whether to automatically add CPE devices that actively access

iMC BIMS

Common Password: If the username and password used by iMC BIMS to connect to a CPE device

are not the same as those for the CPE to access iMC BIMS, common password authentication is
enabled. The common password is bims by default, and you can change it as needed.