8

Item Requirements

Power grounding (AC)

Use a power cord with a protective earth (PE). Do not use a power cord with only
an L line and an N line.

The neutral line of the power cord should not be connected with the PGND of other
communications equipment. The L and N lines cannot be connected.

Lightning rod

In plain areas, the shielding angle of the lightning rod should be less than 45 degrees.
In mountainous areas or lightning areas, the shielding angle should be less than 30

degrees. The lightning protection grounding (for example, the grounding of the

lightning rod) should be connected to the grounding conductor of the equipment
room.

Antenna

The antenna support is already prepared according to the design requirements.

The AP is well grounded according to design requirements.

Network cable

Use a shielded twisted pair cable for outdoor installation. Make sure that the devices
at the two ends of the cable are well grounded.

Examining the AP

Before installing the AP, supply power to the AP, connect the AP to the Ethernet, and check the status of

the LEDs to make sure that the AP is functional. Save the MAC address of the AP for future use.