Preparing for installation

This chapter describes how to prepare for the installation of the AP, including the preparation of tools and

installation site survey.

Preparing installation tools

When installing the AP, you may need the tools listed in

Table 4

. Choose the appropriate tools according

to the installation environment.

Table 4 List of installation tools

Type of tools

Tools

General tools

Digging tools, adjustable wrench, pliers, Phillips screwdriver

Special tools

Cable stripper, crimping pliers, RJ-45 crimping pliers, waterproof sealing tape, fiber
fusion splicer

Auxiliary tools

Ladder

Examining the installation site

Before installation, examine the installation site to make sure that the AP will work in a good environment.
You can examine the installation site from the following two aspects.

Installation site selection

Keep the AP away from high temperature, dust, harmful gases, inflammables, explosive substances,

electromagnetic interference sources (heavy-duty radars, radio stations, or electrical substations),
unstable voltage, heavy vibration, or loud noise. The installation site should be dry, without any leakage,

dripping, or dew. The AP should be at least 500 m (0.31 miles) away from the seaside and should not

face the direction of sea wind.
In engineering design, the site should be selected according to the network planning and technical

requirements of the communications equipment, and the considerations such as climate, hydrology,

geology, earthquake, electric power, and transportation.

Temperature and humidity

Table 5 Temperature and humidity requirements

Item Range

Operating temperature

–40°C to +65°C (–40°F to +149°F)

Storage temperature

–40°C to +85°C (–40°F to +185°F)

Operating relative humidity (noncondensing)

0% to 100%

Storage relative humidity (noncondensing)

0% to 100%