Verifying the configuration – H3C Technologies H3C S6800 Series Switches User Manual
Page 73

65
[SwitchC] l2vpn enable
# Establish an active SSL connection to the controller, and enable the OVSDB service.
[SwitchC] ovsdb server private-key flash:/ovsclient-privkey.pem
[SwitchC] ovsdb server certificate flash:/ovsclient-cert.pem
[SwitchC] ovsdb server ca-certificate flash:/vswitchd.cacert bootstrap
[SwitchC] ovsdb server ssl 10.0.2.15 port 6632
[SwitchC] ovsdb server enable
# Enable VTEP mode.
[SwitchC] vtep enable
# Assign an IP address to Loopback 0. Specify the IP address as the global source address for
VXLAN tunnels.
[SwitchC] interface loopback0
[SwitchC-LoopBack0] ip address 3.3.3.3 255.255.255.255
[SwitchC-LoopBack0] quit
[SwitchC] tunnel global source-address 3.3.3.3
# Specify the site-facing interface FortyGigE 1/0/1 as a VTEP access port.
[SwitchC] interface fortygige 1/0/1
[SwitchC-FortyGigE1/0/1] vtep access port
[SwitchC-FortyGigE1/0/1] quit
5.
Configure VXLAN settings on the controller. (Details not shown.)
Verifying the configuration
1.
Verify the VXLAN settings on the VTEPs. This example uses Switch A.
# Verify that the VXLAN tunnel interfaces on the VTEP are up.
[SwitchA] display interface tunnel 1
Tunnel1
Current state: UP
Line protocol state: UP
Description: Tunnel1 Interface
Bandwidth: 64kbps
Maximum Transmit Unit: 1464
Internet protocol processing: disabled
Last clearing of counters: Never
Tunnel source 1.1.1.1, destination 2.2.2.2
Tunnel protocol/transport UDP_VXLAN/IP
# Verify that the VXLAN tunnels have been assigned to the VXLAN.
[SwitchA] display l2vpn vsi verbose
VSI Name: evpn2014
VSI Index : 0
VSI State : Up
MTU : 1500
Bandwidth : -
Broadcast Restrain : -
Multicast Restrain : -
Unknown Unicast Restrain: -
MAC Learning : Enabled