Configuration procedure – H3C Technologies H3C S6800 Series Switches User Manual
Page 33
26
Configuration procedure
This section provides only TRILL-related configurations.
1.
Configure the downlink ports of access layer devices:
# Enable TRILL globally on RB 3.
[RB3] trill
[RB3-trill] quit
# Enable TRILL on downlink port FortyGigE 1/0/1, and configure the port's link type as access
without the alone attribute.
[RB3] interface fortygige 1/0/1
[RB3-FortyGigE1/0/1] trill enable
[RB3-FortyGigE1/0/1] trill link-type access
[RB3-FortyGigE1/0/1] quit
# Configure RB 4 through RB 6 in the same way you configured RB 3.
2.
Configure the uplink ports of access layer devices:
# On RB 3, enable TRILL on uplink ports FortyGigE 1/0/2 and FortyGigE 1/0/3, and configure
these ports as VR ports.
[RB3] interface fortygige 1/0/2
[RB3-FortyGigE1/0/2] trill enable
[RB3-FortyGigE1/0/2] trill link-type vr
[RB3-FortyGigE1/0/2] quit
[RB3] interface fortygige 1/0/3
[RB3-FortyGigE1/0/3] trill enable
[RB3-FortyGigE1/0/3] trill link-type vr
[RB3-FortyGigE1/0/3] quit
# Configure RB 4 through RB 6 in the same way you configured RB 3.
3.
Configure the downlink ports of distribution layer devices:
# Enable TRILL globally on RB 1.
[RB1] trill
[RB1-trill] quit
# Enable TRILL on downlink ports FortyGigE 1/0/1 through FortyGigE 1/0/4, and configure
these ports as VR ports.
[RB1] interface fortygige 1/0/1
[RB1-FortyGigE1/0/1] trill enable
[RB1-FortyGigE1/0/1] trill link-type vr
[RB1-FortyGigE1/0/1] quit
[RB1] interface fortygige 1/0/2
[RB1-FortyGigE1/0/2] trill enable
[RB1-FortyGigE1/0/2] trill link-type vr
[RB1-FortyGigE1/0/2] quit
[RB1] interface fortygige 1/0/3
[RB1-FortyGigE1/0/3] trill enable
[RB1-FortyGigE1/0/3] trill link-type vr
[RB1-FortyGigE1/0/3] quit