beautypg.com

Configuring the drb priority of a trill port, Configuring the link cost for a trill port – H3C Technologies H3C S6800 Series Switches User Manual

Page 18

background image

11

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2 Ethernet
or aggregate

interface view.

interface interface-type
interface-number

N/A

3.

Configure the link
type of the TRILL port.

trill link-type { access [ alone ] |
hybrid | trunk | vr }

By default, the link type of a TRILL port is
access without the alone attribute.

Configuring the DRB priority of a TRILL port

On a broadcast network, TRILL must elect a DRB. An RB with a higher DRB priority is preferred in DRB

election. When two RBs have the same DRB priority, the RB with a higher MAC address takes

precedence.
To configure the DRB priority of a TRILL port:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2 Ethernet or

aggregate interface
view.

interface interface-type
interface-number

N/A

3.

Configure the DRB
priority of the TRILL port. trill drb-priority priority

By default, the DRB priority of a TRILL port is
64.

Configuring the link cost for a TRILL port

The link cost of a TRILL port can be automatically calculated by the system or manually configured.

A manually configured link cost takes precedence over a calculated link cost.

If no configured link cost exists and automatic link cost calculation is enabled, the calculated link
cost takes effect.

If no configured link cost exists and automatic link cost calculation is disabled, the default link cost
of 2000 is used.

The system automatically calculates the link cost of a TRILL port by using the following formula: link cost

= 20000000000000/interface baud rate.
To configure the link cost for a TRILL port:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter TRILL view.

trill

N/A

3.

Enable automatic link cost
calculation for TRILL ports.

auto-cost enable

By default, automatic link cost
calculation is enabled for TRILL

ports.

4.

Return to system view.

quit

N/A

This manual is related to the following products: