![background image](https://www.manualsdir.com/files/812653/content/doc094.png)
84
Field Remarks
Transceiver info I/O error
Transceiver information read and write error
Transceiver info checksum error
Transceiver information checksum error
Transceiver type and port
configuration mismatch
The type of the transceiver module does not match the port
configuration.
Transceiver type not supported by
port hardware
The port does not support this type of transceiver modules.
# Display the currently measured values of the fault detection parameters of the transceiver plugged in
interface GigabitEthernet 3/0/1.
GigabitEthernet3/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 25 Command output
Field Description
transceiver diagnostic information Digital diagnosis information of the transceiver module on the interface.
Temp.(°C)
Digital diagnosis parameter—Temperature, in °C, accurate to 1°C.
Voltage(V)
Digital diagnosis parameter—Voltage, in V, accurate to 0.01 V.
Bias(mA)
Digital diagnosis parameter—Bias current, in mA, accurate to 0.01 mA.
RX power(dBM)
Digital diagnosis parameter—RX power, in dBM, accurate to 0.01 dBM.
TX power(dBM)
Digital diagnosis parameter—TX power, in dBM, accurate to 0.01 dBM.