H3C Technologies H3C S12500 Series Switches User Manual
Page 82

72
DC output voltage information:
Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status
---- -------- ------------------ ------------------ -------
1 49.96 51.00 49.00 Normal
DC output current information:
Total current(A): 8.60
Branch Value(A)
------ --------
1/1 N/A
1/2 N/A
1/3 N/A
1/4 8.60
1/5 N/A
1/6 N/A
PSU Status:
ID Status Input-Err Output-Err High-Temperature Fan-Err Closed Current-Limit
-- ------- ----------- ---------- ---------------- ------- ------ -------------
1/1 Absent
1/2 Absent
1/3 Absent
1/4 Normal
1/5 Absent
1/6 Absent
Line-card power status:
Slot Board-Type Watts Status
---- --------------- ----- ------
2 None -- Absent
3 None -- Absent
4 None -- Absent
5 None -- Absent
6 None -- Absent
7 None -- Absent
8 LST1GT48LEC1 190 On
9 None -- Absent
Table 17 Command output
Field Description
System power-supply policy:
Configurations of the power management function.
System power-module redundant(configured):
Number of redundant power supplies configured in the
system.
System power usable:
Power currently available in the system, in watts.
System power redundant(actual):
Redundant power currently available in the system, in watts.
System power allocated:
Power that has been allocated, in watts.