Run led, Switching fabric module leds – H3C Technologies H3C S12500 Series Switches User Manual
Page 144

134
Table 55 Interface LED description
LED Status
Description
LINK/ACT
Steady on
A link is present.
Off
No link is present.
Flashing
Data is being transmitted and/or received on the interface.
RUN LED
Table 56 RUN LED description
LED Status Description
RUN (green-red)
Flashing green
The LPU is operating properly.
Flashing red
The LPU is faulty.
Steady on
The LPU is faulty.
Off
The LPU is faulty or not in position.
NOTE:
The RUN LED description of different S12500 LPU models is the same.
Switching fabric module LEDs
Table 57 Interface LED description
LED Status Description
LINK
Off
No link is present.
Steady on
A link is present.
ACT
Off
No data is being transmitted or received.
Flashing
Data is being transmitted and/or received.
Table 58 RUN LED description
LED Status
Description
RUN (green-red)
Flashing green
The switching fabric module is operating properly.
Flashing red
The switching fabric module is faulty.
Steady on
The switching fabric module is faulty.
Off
The switching fabric module is faulty or not in position.
NOTE:
The LED description of different S12500 switching fabric modules is the same.