H3C Technologies H3C S12500 Series Switches User Manual
Page 78
68
Step Command
Remarks
3.
Allocate new IDs for
the specified AC
power supplies.
•
In standalone mode:
power-supply module old-id-list new-id new-id-list
•
In IRF mode:
power-supply module chassis chassis-number
old-id-list new-id new-id-list
By default, the
system allocates IDs
for AC power
supplies randomly.
Displaying the power supply system information about your
switch
Use the display power-supply command to display power supply system information about your switch,
including whether power management is enabled, the number of configured redundant power supplies,
power, output voltage and current, and whether each card is powered on.
•
In standalone mode:
# Display detailed information about the power supply system.
Power info on chassis 0:
System power-supply policy: enable
System power-module redundant(configured): 1
System power usable: 18000 Watts
System power redundant(actual): 2000 Watts
System power allocated: 2620 Watts
System power available: 15380 Watts
SYSTEM POWER USED(CURRENT): 470.00 Watts
System power monitoring unit:
Software version: 100
Type In/Out Rated-Vol(V) Existing Usable Redundant(actual)
---------- ------ ------------ -------- ------ -----------------
PSE9000 AC/DC 220(default) 10 9 1
DC output voltage information:
Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status
---- -------- ------------------ ------------------ -------
1 50.00 53.00 47.00 Normal
2 50.00 53.00 47.00 Normal
DC output current information:
Total current(A): 2.00
Branch Value(A)
------ --------
1/1 N/A
1/2 0.90
1/3 1.40
1/4 0.80
1/5 1.50