ARM Electronics RT8-16CD User Manual
Page 46
MENU FUNCTION
-41-
6.4.6 System
In this menu list, you can check or change some system settings.
Move the cursor to “SYSTEM”, and press ”ENTER”. You will see a similar screen as the following:
ADVANCE
SYSTEM
CAMERA
SERIAL TYPE
RS-485
DETECTION
BAUD RATE
02400
DISPLAY
HOST ID
001
ALERT
IR
ON
REMOTE
PASSWORD
SETUP
SYSTEM
RESET DEFAULT
RESET
NETWORK
CLEAR HDD
EXT 003
BACKUP
UPGRADE
NO
HDD INFO
R.E.T.R. (MIN)
03
EVENT LOG
AUTO KEYLOCK
NEVER
LANGUAGE
ENGLISH
VERSION
1088-10-K2-04-AA-11
VIDEO FORMAT
NTSC
The submenu items are described below:
1) SERIAL TYPE
Press “ENTER” or “
+” / “-” button to set the serial type of the DVR (RS-485 / RS-232).
2) BAUD RATE
Press “ENTER” or “
+” / “-” button to set the baud rate of the DVR (2400 / 9600 / 19200 / 57600).
3) HOST ID
Press “ENTER” or “
+” / “-” button to set the ID of the DVR (0 ~ 255).
4) IR
Press “ENTER” or “
+” / “-” button to enable or disable IR function (ON / OFF).
5) PASSWORD
Press “ENTER” to reset the password for accessing the DVR system (ADMIN PASSWORD or GUEST PASSWORD).
You can set the password up to 4 digits.
Note: Users who use guest password to access the DVR will be only allowed to view the live streaming video
and sequence display, shift the channel display, and lock keys.
6) RESET DEFAULT
Press “ENTER” to reset all settings as default, and select “YES” to confirm or “NO” to cancel.
7) CLEAR HDD
Press “ENTER”, and select “YES” to confirm to clear HDD or “NO” to cancel.
8) UPGRADE
Press “ENTER”, and select “YES” to confirm upgrade or “NO” to cancel.