beautypg.com

3 rs485 setup – ARM Electronics DVRCD120 User Manual

Page 41

background image

User’s Manual

40

4.6.3

RS485 Setup

Full-featured MPEG-4 DVR controls the domes via RS-485 communication

protocol. The RS-485 parameters of Full-featured MPEG-4 DVR must be set

to the same as the parameters set in dome camera .

Users are allowed to change the RS-485 settings of the Full-featured

MPEG-4 DVR. Select in Main menu, then select

Setup> from the System Setup menu and press ENTER. The following menu

is displayed.

RS485 Setup

1 Unit ID
2 Baud Rate
3 Bits
4 Stop
5 Parity

224

9600

8
1

None

The ID number must match the ID address set by the dome. The Unit ID is in

the range of 1 to 255. The default ID is 224. Note that no two devices on the

same bus should be given the same ID address, or a conflict may occur.

The default Full-featured MPEG-4 DVR RS-485 settings are 9600 Baud, 8

Data Bits, 1 Stop Bit and No Parity.

NOTE: The settings become effective after saving the changes and

exiting from the menu.